We use cookies to understand how customers use the site and to measure our advertising. See our Privacy Policy.
Guide
Fire ratings for event graphics, explained
NFPA 701, ASTM E84, Class A: what the fire marshal actually wants, translated for people with a show to open.
Every event producer eventually has this moment: the booth is half-built, move-in ends at six, and someone with a clipboard asks whether the fabric backdrop is “701 certified.” This guide exists so that moment is boring. Two standards cover almost everything printed at an event. Here they are in plain language.
The two tests, translated
NFPA 701: for things that hang
The flame-propagation standard for textiles and films: drapes, fabric backdrops, hanging banners, tension-fabric structures. The test burns a sample and measures whether flame spreads or self-extinguishes. If your graphic hangs in a public assembly space (and a convention center is exactly that), this is the standard the venue means, even when the exhibitor kit just says “flame retardant.”
ASTM E84: for things that are mounted
The “tunnel test” for building materials: rigid panels, wall coverings, and anything that becomes part of a wall or ceiling surface. It scores two numbers, flame spread and smoke developed, and buckets materials into classes: Class A (flame spread 0–25), Class B (26–75), Class C (76–200). Building codes dictate which class a space requires. Large-scale booth walls and scenic builds live under this standard.
Rule of thumb: if it hangs, think NFPA 701; if it’s mounted to structure, think ASTM E84. When a piece is ambiguous (a stretched fabric wall, say), the venue’s answer wins. Ask them, in writing.
What passes and what doesn’t
- Display fabrics: most professional dye-sub display polyesters are inherently flame retardant (IFR) and certified to NFPA 701 by the mill. The rating is in the fiber, not a spray coating that washes out.
- Banner vinyl: widely available with NFPA 701 certification, but not universal. It’s a spec you choose at ordering time, which is why “it’s for a convention center” is a useful thing to tell your printer.
- Paper and standard foam board: generally unrated. Fine for a poster on an easel; a problem when it covers a wall. At architectural scale, spec a rated substrate instead.
The move-in day checklist
- Read the exhibitor kit’s fire regulations page before you order anything printed.
- Tell your printer the piece is for a public venue. The rated material is a spec choice, not an upgrade you can apply after printing.
- Collect certification documents for every large or hanging piece, and carry them (printed and on your phone) at move-in.
- For California events, confirm CA State Fire Marshal registration specifically. It’s the strictest common jurisdiction.
- When in doubt, email the venue’s event services team and keep the reply.
Frequently asked questions
What fire rating do I need for a trade show banner?
Hanging banners and fabric graphics in convention centers typically need to meet NFPA 701, the flame propagation standard for textiles and films. Check your exhibitor kit: most major venues state their requirement explicitly, and the fire marshal can ask for documentation on-site.
What is the difference between NFPA 701 and ASTM E84?
NFPA 701 tests hanging textiles and films for how they propagate flame: drapes, banners, fabric structures. ASTM E84 tests surface burning of building materials like rigid panels and wall finishes, and scores them Class A, B, or C. Short version: if it hangs, think 701; if it is mounted to the structure, think E84.
What does Class A fire rated mean?
Class A is the best score under ASTM E84: a flame spread index of 25 or less (and smoke developed index of 450 or less). Class B runs 26–75 and Class C 76–200. Building codes specify which class an interior finish material needs based on the space and its use.
What will the fire marshal actually ask for?
Documentation: a certificate or spec sheet showing the material meets the required standard. In some jurisdictions they can also perform a field flame test on a sample. Have the paperwork with you at the venue; producing it on the spot ends the conversation quickly.
Is California different?
Yes. California is the strictest common case. The State Fire Marshal maintains its own registration program for flame-retardant fabrics and treatments used in public assembly spaces, so a material that satisfies a venue elsewhere may need CA SFM-registered certification in California. Ask early if your event is there.
Are paper posters and foam boards fire rated?
Generally no. Standard paper and many foam boards carry no fire rating, which is fine for small pieces but matters at architectural scale. If you are covering large areas of a booth or venue wall, ask us to spec a rated material instead.
Printing for a venue with fire requirements?
Tell us the venue and we’ll spec materials that meet its requirements, with the documentation to prove it when someone with a clipboard asks.